Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Grivory G 16 natural - PA6I/6T - EMS-GRIVORY | a unit of EMS-CHEMIE AG

Material Data Center offers the following functions for Grivory G 16 natural:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Grivory datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Testo del prodotto
Product-nomenclature: ISO 16396-PA6I/6T,,FT,S09-030

 

Co Polyamide

Partially aromatic Polyamide

Product Attributes

  Highly transparent, Barrier material, Improved UV resistance (outdoor use)

Markets

  Packaging
  Paper coating, Cosmetics / Personal care

Approvals

  Food Contact
  EU Requirements, FDA
Caratteristiche Fisichesecco/condUnitáNorma del test
ISO Data
Indice di fusione di volume, MVR 100 / * cm³/10min ISO 1133
Temperatura 275 / * °C -
Carico 5 / * kg -
Proprietà Meccanichesecco/condUnitáNorma del test
ISO Data
Modulo a trazione 3000 / 3000 MPa ISO 527
Carico unitario a trazione 100 / 100 MPa ISO 527
Deformazione a snervamento 5 / 5 % ISO 527
Deformazione nominale a rottura >50 / >50 % ISO 527
Resistenzia all'urto Charpy con intaglio, +23°C 8 / 8 kJ/m² ISO 179/1eA
Resistenzia all'urto Charpy con intaglio, -30°C 8 / 2 kJ/m² ISO 179/1eA
Proprietà Termichesecco/condUnitáNorma del test
ISO Data
Temperatura di transizione vetrosa, 10°C/min 125 / * °C ISO 11357-1/-2
Proprietà Ottichesecco/condUnitáNorma del test
ISO Data
Brillantezza, 60° 160 / * - ISO 2813
Altre Proprietàsecco/condUnitáNorma del test
Assorbimento d'acqua 7 / * % Sim. alla ISO 62
Assorbimento d'umidità 2 / * % Sim. alla ISO 62
Massa volumica 1180 / - kg/m³ ISO 1183
Proprietà Meccaniche (Film)secco/condUnitáNorma del test
ISO Data
Carico allo snervamento, parallelo 85 / * MPa ISO 527-3
Carico allo snervamento, perpend. 85 / * MPa ISO 527-3
Allungamento allo snervamento, parallelo 5 / * % ISO 527-3
Allungamento allo snervamento, perpend. 5 / * % ISO 527-3
Allungamento massimo, parallelo 200 / * % ISO 527-3
Allungamento massimo, perpend. 200 / * % ISO 527-3
Resistenza alla lacerazione Elmendorf, parallelo 10 / * N ISO 6383-2
Resistenza alla lacerazione Elmendorf, perpend. 10 / * N ISO 6383-2
Resistenza alla lacerazione Trouser, parallelo 5 / * N/mm ISO 6383-1
Resistenza alla lacerazione Trouser, perpend. 5 / * N/mm ISO 6383-1
WVTR, 23°C/85%r.h. 7 / * g/(m²*d) ISO 15106-1/-2
Permeabilità all' Ossigeno, 23°C/0%r.h. 30 / * cm³/(m²*d*bar) ISO 15105-1/-2
Permeabilità all' Ossigeno, 23°C/85%r.h. 10 / * cm³/(m²*d*bar) ISO 15105-1/-2
Permeabilità al CO2, 23°C/0%r.h. 90 / * cm³/(m²*d*bar) ISO 15105-1/-2
Permeabilità al CO2, 23°C/85%r.h. 40 / * cm³/(m²*d*bar) ISO 15105-1/-2
Caratteristiche
Processabilità e Forma di Forni
Stampaggio ad Iniezione, Estrusione Film, Rivestimento, Soffiaggio
Forma fisica disponibile
Granuli, Colore naturale
Caratteristiche speciali
Estab. agli U.V. o per applicaz.in esterni, Trasparente
Caratteristiche
Proprietà di barriera, Copolimero
Certifications
Contatto con gli alimenti, Approvato per l'utilizzo per contatto con alimenti secondo la FDA 21 CFR
Applicazioni
Imballaggio
Disponibilità geografica
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.