Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of ALTECH PC A 2030/100 GF30 - PC-GF30 - MOCOM Compounds GmbH & Co. KG

Material Data Center offers the following functions for ALTECH PC A 2030/100 GF30:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Altech datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informations produit
Base PolymerPolycarbonate
Filler/Additive System30 % glass fibres
Special Featuresgood flow
Market SegmentAutomotive,electrical and electronic
Typical Applicationsthin walled parts,housings
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Indice de fluidité à chaud en volume, MVR 15 cm³/10min ISO 1133
Température 300 °C -
Charge 1.2 kg -
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 6300 MPa ISO 527
Contrainte à la rupture 75 MPa ISO 527
Déformation à la rupture 2.4 % ISO 527
Résistance au choc Charpy, +23°C 40 kJ/m² ISO 179/1eU
Résistance au choc Charpy (entaillé), +23°C 5 kJ/m² ISO 179/1eA
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fléchissement s/chrg, 1.80 MPa 139 °C ISO 75-1/-2
Température de ramolliss. Vicat, B 144 °C ISO 306
Inflammabilité ep. nom. 1.5 mm HB class IEC 60695-11-10
Epaisseur de l'éprouvette 1.5 mm -
Propriétés diversesValeurUnitéNorme du test
Masse volumique 1420 kg/m³ ISO 1183
Caractéristiques
Transformation
Moulage par injection
Disponibilité régionale
Autres informations
Moulages par injection
Pre-Drying Conditions120 °C in a dry air (dessiccant) dryer
for 2-3 h
120 °C in an air circulating dryer
for 4-12 h
dependant on moisture content
max. moisture content <0,02 %
Processing Injection Mouldingmelt temperature 270-310 °C
mould temperature 80-110 °C
Storagedry, protected from light
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.