Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of FORTRON® 1140L6 - PPS-GF40 - Celanese

Material Data Center offers the following functions for FORTRON® 1140L6:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Fortron datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
Fortron 1140L6 is an easier flow version of Fortron 1140L4. It offers essentially the same characteristics of 1140L4. Especially used for thin walled parts with long flow lengths. Applications made of this grade include components for pumps and electronics.

Flammability @1.6mm nom. thickn.V-0-
Flammability at thickness h (0.38 mm)V-0-
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Molding shrinkage, parallel 0.3 % ISO 294-4, 2577
Molding shrinkage, normal 0.6 % ISO 294-4, 2577
Spec. heat capacity of melt 1500 J/(kg K) -
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 14700 MPa ISO 527
Stress at break 195 MPa ISO 527
Strain at break 1.9 % ISO 527
Charpy impact strength, +23°C 53 kJ/m² ISO 179/1eU
Charpy impact strength, -30°C 53 kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 10 kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C 10 kJ/m² ISO 179/1eA
Thermal propertiesValueUnitTest Standard
ISO Data
Melting temperature, 10°C/min 280 °C ISO 11357-1/-3
Glass transition temperature, 10°C/min 90 °C ISO 11357-1/-2
Temp. of deflection under load, 1.80 MPa 270 °C ISO 75-1/-2
Temp. of deflection under load, 8.00 MPa 215 °C ISO 75-1/-2
Coeff. of linear therm. expansion, parallel 26 E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 42 E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. V-0 class IEC 60695-11-10
Thickness tested 1.5 mm -
Burning Behav. at thickness h V-0 class IEC 60695-11-10
Thickness tested 0.4 mm -
Electrical propertiesValueUnitTest Standard
ISO Data
Relative permittivity, 1MHz 4.2 - IEC 62631-2-1
Dissipation factor, 1MHz 20 E-4 IEC 62631-2-1
Volume resistivity >1E13 Ohm*m IEC 62631-3-1
Surface resistivity 1.3E14 Ohm IEC 62631-3-2
Other propertiesValueUnitTest Standard
Water absorption 0.02 % Sim. to ISO 62
Density 1650 kg/m³ ISO 1183
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Release agent
Certifications
Drinking water contact
Applications
Electrical and Electronical
Regional Availability
North America, Europe, South and Central America, Near East/Africa
Other text information
Injection molding
Predrying in a dehumidified air dryer at 130 - 140 degC/3-4 hours is recommended.
On injection molding machines with 15-25 D long three-section screws, as are usual in the trade, the FORTRON is processable. A shut-off nozzle is preferred to a free-flow nozzle.

Melt temperature 320-340 degC
Mold wall temperature at least 140 degC

A medium injection rate is normally preferred. All mold cavities must be effectively vented.
Tool temperature of at least 135 degC is recommended for parts to achieve maximum crystallizable potential.
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.