Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Delrin® 111P NC010 - POM - DuPont Engineering Polymers

Material Data Center offers the following functions for Delrin® 111P NC010:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other Delrin datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical CharacteristicsValueUnitTest Standard
ASTM Data
Melt Flow Index, MFI 1 g/10min ASTM D 1238
Temperature 190 °C -
Load 1.05 kg -
Mold Shrinkage, MD 0.0195 mm/mm ASTM D 955
Mold Shrinkage, TD 0.0185 mm/mm ASTM D 955
Mechanical propertiesValueUnitTest Standard
ASTM Data
Tensile Modulus 3000 MPa ASTM D 638
Tensile Strength 72 MPa ASTM D 638
Tensile Strength at Yield 72 MPa ASTM D 638
Elongation at Yield 21 % ASTM D 638
Elongation at Break 73 % ASTM D 638
Flexural Modulus 2970 MPa ASTM D 790
Rockwell Hardness R 121 - ASTM D 785
Izod Impact notched, 1/8 in 96 J/m ASTM D 256
Thermal propertiesValueUnitTest Standard
ASTM Data
UL 94 Flame rating HB - UL 94
Thickness tested 1.5 mm -
Coefficient of Thermal Expansion, MD 110 E-6/K ASTM D 696
Coefficient of Thermal Expansion, TD 110 E-6/K ASTM D 696
DTUL @ 66 psi 169 °C ASTM D 648
DTUL @ 264 psi 110 °C ASTM D 648
Melting Temperature 178 °C ASTM D 3418
Electrical propertiesValueUnitTest Standard
ASTM Data
Dielectric Strength, Short Time 18 kV/mm ASTM D 149
Dissipation Factor, 1 MHz 0.005 - ASTM D 150
Dielectric Constant, 1 MHz 3.7 - ASTM D 150
Surface Resistivity 6E14 Ohm ASTM D 257
Volume Resistivity 8E14 Ohm*cm ASTM D 257
Other propertiesValueUnitTest Standard
Water Absorption, 24hr 0.3 % ASTM D 570
Density 1420 kg/m³ ASTM D 792
Characteristics
Processing
Injection Molding, Film Extrusion, Pipe/Tube Extrusion, Profile Extrusion, Sheet Extrusion, Wire/Cable Extrusion, Other Extrusion
Delivery form
Pellets, Natural Color
Additives
Lubricants, Release agent
Special Characteristics
High impact or impact modified
Features
Creep Resistance, Fatigue Resistance, Low Warpage, Thermal Stability, Weldable, Homopolymer
Regional Availability
North America, Europe, Asia Pacific, South and Central America, Near East/Africa
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.