Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAKEEP® Care M40 3DF - PEEK - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAKEEP® Care M40 3DF:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vestakeep datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
商品の説明文
Filament based on high viscosity, unreinforced polyether ether ketone (PEEK) for 3D printed medical devices

VESTAKEEP® Care M40 3DF is extruded from naturally colored, high viscosity VESTAKEEP® Care M40 G PEEK resin. The material is designed for 3d printing of medical devices with up to 30 days body contact.  

Biocompatibility
The biocompatibility of the base resin VESTAKEEP® Care M40 G has been tested following ISO 10993-1 recommendations for medical devices with up to 30 days of body contact and USP Class VI. A summary of biocompatibility test results is available upon request.

Biocompatibility tests available for VESTAKEEP® Care M40 G:

Delivery and packaging
VESTAKEEP® Care M40 3DF filament has a diameter of 1.75 mm ( /- 0.04 mm*). It is supplied on TROGAMID®-spools with 500g. The spools are packaged in double bags to facilitate transfer into clean areas.

The properties listed are for information only and only apply to the VESTAKEEP® Care M40 G resin used in the manufacture of VESTAKEEP® Care M40 3DF. The performance and the purity of any parts manufactured from VESTAKEEP® Care M40 3DF are highly dependent on any 3D- or additive-printing processes, or any other processing, to which the filament is subjected.
Only density and filament diameter apply to VESTAKEEP® Care M40 3DF directly.

*Diameters are tested by a multi-axis laser gauge. The diameter is the average of these axis.
 
FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.EVONIK.COM/MEDICAL-TECHNOLOGY
Processing/Physical Characteristics単位テスト基準
ISO データ
メルトボリュームレイト, MVR 11 cm³/10min ISO 1133
温度 380 °C -
荷重 5 kg -
機械的特性単位テスト基準
ISO データ
引張弾性率 3500 MPa ISO 527
引張強度 94 MPa ISO 527
降伏応力 94 MPa ISO 527
降伏ひずみ 5 % ISO 527
シャルピー衝撃強さ, +23°C N kJ/m² ISO 179/1eU
シャルピー衝撃強さ, -30°C N kJ/m² ISO 179/1eU
ノッチ付きシャルピー衝撃強さ, +23°C 7 kJ/m² ISO 179/1eA
Type of failure C - -
ノッチ付きシャルピー衝撃強さ, -30°C 6 kJ/m² ISO 179/1eA
Type of failure C - -
熱的特性単位テスト基準
ISO データ
溶融温度, 10°C/min 335 °C ISO 11357-1/-3
ガラス転移点, 10°C/min 152 °C ISO 11357-1/-2
荷重たわみ温度, 1.80 MPa 155 °C ISO 75-1/-2
荷重たわみ温度, 0.45 MPa 205 °C ISO 75-1/-2
ビカット軟化温度, A 335 °C ISO 306
ビカット軟化温度, B 305 °C ISO 306
線膨張係数, 平行 60 E-6/K ISO 11359-1/-2
厚さhでの燃焼性 V-0 class IEC 60695-11-10
試験片の厚さ 3.2 mm -
ASTM数据
溶融温度 335 °C ASTM D 3418
その他の特性.単位テスト基準
吸水率 0.4 % Sim. to ISO 62
密度 1300 kg/m³ ISO 1183
密度 1300 kg/m³ ASTM D 792
特殊な特性
成形加工法.
Additive Manufacturing
納入形状.
Monofilament, ナチュラルカラー
特殊な特性.
熱安定化., Opaque
な特性
Thermal Stability
耐薬品性
Acid Resistance, Alkali Resistance, General Chemical Resistance, Solvent Resistance, Grease Resistance, Hydrolytically Stable, Oil Resistance, Oxidation Resistance
Certifications
Medical Grade, US Pharmacopeia Class VI Approved
アプリケーション
医療の
領域別の利用可能性
ヨーロッパ.
その他の情報
その他の押出成形.
Drying recommendations

We recommend to dry the filament prior to usage to avoid stringing, bubbles, or other defects. 

a) Filament on spool: minimum 12 hours at 80°C to 100°C. 100°C must not be exceeded to avoid distortion of the spool.
b) Filament removed from spool: minimum 4 hours at 130°C to 140°C.
 
The maximum drying temperature of the filament is 140°C. Please also pay attention to the instructions of your drying device.



Spool dimensions

For dimensions of the spool, please see drawing below. All dimensions are given in millimeter (mm).
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.