Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of ULTEM™ Resin 2310F - PEI-GF30 - Saudi Basic Industries Corporation (SABIC)

Material Data Center offers the following functions for ULTEM™ Resin 2310F:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Ultem datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Testo del prodotto
ULTEM 2310F resin is an improved flow 30% glass fiber reinforced polyetherimide resin. The material has global food contact approvals (FDA, CN, EC). The material is RoHS compliant and is intrinsically flame retardant without the use of FR modifiers. It offers UL94 V0 and 5VA ratings. The material can also offer excellent dimension stability, strength, stiffness and creep resistance up to high temperature due to its high glass transition temperature of 217°C. The material is opaque and can be custom colored.
Caratteristiche FisicheValoreUnitáNorma del test
ISO Data
Indice di fusione di volume, MVR 8 cm³/10min ISO 1133
Temperatura 360 °C -
Carico 5 kg -
ASTM Data
Indice di fluidità a caldo, MFI 7.6 g/10min ASTM D 1238
Temperatura 337 °C -
Carico 6.6 kg -
Proprietà MeccanicheValoreUnitáNorma del test
ISO Data
Modulo a trazione 10500 MPa ISO 527
Carico unitario a rottura 175 MPa ISO 527
Deformazione a rottura 2.4 % ISO 527
Modulo a flessione, 23°C 9600 MPa ISO 178
Resistenza all'urto Charpy, +23°C 40 kJ/m² ISO 179/1eU
Resistenza all'urto Charpy, -30°C 40 kJ/m² ISO 179/1eU
Resist. urto Charpy con intaglio, +23°C 10 kJ/m² ISO 179/1eA
Resist. urto Charpy con intaglio, -30°C 10 kJ/m² ISO 179/1eA
Resistenza all'urto Izod, +23°C 40 kJ/m² ISO 180/1U
Resistenza all'urto Izod con intaglio, +23°C 10 kJ/m² ISO 180/1A
Resistenza all'urto Izod con intaglio 10 kJ/m² ISO 180/1A
Temperatura -30 °C -
Durezza Rockwell M 110 - ISO 2039-2
Ball indentation hardness 165 MPa ISO 2039-1
ASTM Data
Modulo a trazione 10400 MPa ASTM D 638
Resistenza alla trazione a rottura 175 MPa ASTM D 638
Allungamento a rottura 2.5 % ASTM D 638
Modulo a flessione 9700 MPa ASTM D 790
Durezza Rockwell M 114 - ASTM D 785
Resistenza all'urto Izod con intaglio, 1/8 in 90 J/m ASTM D 256
Resistenza all'urto Izod con intaglio, basso temperatura 80 J/m ASTM D 256
Temperatura -30 °C -
Resistenza all'urto Izod, 1/8 in 600 J/m ASTM D 256
Proprietà TermicheValoreUnitáNorma del test
ISO Data
Temp.di inflessione sotto carico, 1.80 MPa 210 °C ISO 75-1/-2
Temp.di inflessione sotto carico, 0.45 MPa 215 °C ISO 75-1/-2
Temp.di rammollimento Vicat, A 225 °C ISO 306
Temp.di rammollimento Vicat, B 213 °C ISO 306
Coeff.di dilatazione termica lin., parallelo 17 E-6/K ISO 11359-1/-2
Coeff.di dilatazione termica lin. , perpend. 49 E-6/K ISO 11359-1/-2
Reazione al fuoco a spessore h V-0 class IEC 60695-11-10
Spessore provato 0.2 mm -
Yellow Card disponibile - -
Reazione al fuoco 5V a spess. h 5VA class IEC 60695-11-20
Spessore provato 1.2 mm -
Yellow Card disponibile - -
Indice di ossigeno 48 % ISO 4589-1/-2
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (1) 2 mm -
Glow Wire Ignition Temperature (GWIT) 900 °C IEC 60695-2-13
GWIT - thickness tested (1) 2 mm -
ASTM Data
coefficiente d’espansione termica, lung. 19 E-6/K ASTM D 696
Coefficiente d’espansione termica, tras. 41 E-6/K ASTM D 696
DTUL a 66 psi 215 °C ASTM D 648
DTUL a 264 psi 211 °C ASTM D 648
Proprietà ElettricheValoreUnitáNorma del test
ISO Data
Costante dielettrica relativa, 1MHz 3.4 - IEC 62631-2-1
Fattore di dissipazione, 1MHz 23 E-4 IEC 62631-2-1
Resistività volumica 1E13 Ohm*m IEC 62631-3-1
Resistività superficiale >1E15 Ohm IEC 62631-3-2
Rigidità dielettrica 35 kV/mm IEC 60243-1
Res. Alle correnti striscianti superficiali 150 - IEC 60112
ASTM Data
Rigidità elettrica, breve periodo di tempo 24.8 kV/mm ASTM D 149
Resistenza di volume 3E16 Ohm*cm ASTM D 257
Resistenza all’arco 90 s ASTM D 495
Altre ProprietàValoreUnitáNorma del test
Assorbimento d'acqua 0.9 % Sim. alla ISO 62
Assorbimento d'umidità 0.6 % Sim. alla ISO 62
Massa volumica 1510 kg/m³ ISO 1183
Assorbimento d’acqua, 24hr 0.16 % ASTM D 570
Assorbimento d’acqua, equilibrio 0.9 % ASTM D 570
Densità 1510 kg/m³ ASTM D 792
Raccomandazione de Processabilità Stampaggio ad IniezioneValoreUnitáNorma del test
Pre-essiccamento - Temperatura 150 °C -
Pre-essiccamento - Tempo 4 - 6 h -
Umidità del Processo ≤0.02 % -
Temperatura di fusione 350 - 410 °C -
Temperatura dello stampo 135 - 180 °C -
Temperatura - Zona di Alimentazione 80 - 120 °C -
Zona 1 330 - 400 °C -
Zona 2 340 - 410 °C -
Zona 3 345 - 420 °C -
Temperatura dell ugello 345 - 410 °C -
Velocità di Rotazione della Vite 40 - 70 rpm -
Contropressione 0.3 - 1.5 MPa -
Caratteristiche
Processabilità e Forma di Forni
Stampaggio ad Iniezione, Estrusione Profilati, Estrusione di Lastre/Fogli, Altre Estrusioni, Stampaggio a compressione
Caratteristiche speciali
Ritardante di fiamma, Senza alogeni, Stabilizzato o stabile al calore, Opaque, Gamma irradiation sterilization
Caratteristiche
Amorfo, Resistenza al scorrimento, Buona adesione, Fumo basso
Resistenza Chimica
Resistenza chimica generale, Stabilità idrolitica , Resistenza alla radiazione
Certifications
Contatto con gli alimenti, RoHS
Applicazioni
Imballaggio
Disponibilità geografica
Nord America, Europa, South and Central America
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.