Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Grivory HB 5299 natural - PA* - EMS-GRIVORY | a unit of EMS-CHEMIE AG

Material Data Center offers the following functions for Grivory HB 5299 natural:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Grivory datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Testo del prodotto
Product-nomenclature: ISO 16396-PA MXD6/MXDI,,FNST,C12-060

 

Partially aromatic Polyamide

Transparent Polyamide

Product Attributes

  High viscosity, Highly transparent, Barrier material

Markets

  Packaging
  Blow moulded containers, Injectionstretchblowmoulded containers, Non oriented film, Oriented film,
Paper coating, Tubes, Medical packaging

Approvals

  Food Contact
  EU Requirements, FDA
Caratteristiche Fisichesecco/condUnitáNorma del test
ISO Data
Indice di fusione di volume, MVR 50 / * cm³/10min ISO 1133
Temperatura 275 / * °C -
Carico 5 / * kg -
Proprietà Meccanichesecco/condUnitáNorma del test
ISO Data
Modulo a trazione 4000 / 4000 MPa ISO 527
Proprietà Termichesecco/condUnitáNorma del test
ISO Data
Temperatura di fusione, 10°C/min 218 / * °C ISO 11357-1/-3
Proprietà Ottichesecco/condUnitáNorma del test
ISO Data
Brillantezza, 60° 150 / * - ISO 2813
Altre Proprietàsecco/condUnitáNorma del test
Assorbimento d'acqua 5.5 / * % Sim. alla ISO 62
Assorbimento d'umidità 2 / * % Sim. alla ISO 62
Massa volumica 1210 / - kg/m³ ISO 1183
Proprietà Meccaniche (Film)secco/condUnitáNorma del test
ISO Data
Allungamento massimo, parallelo 4.5 / * % ISO 527-3
Allungamento massimo, perpend. 3.5 / * % ISO 527-3
Resistenza alla lacerazione Elmendorf, parallelo 5 / * N ISO 6383-2
Resistenza alla lacerazione Elmendorf, perpend. 5 / * N ISO 6383-2
Resistenza alla lacerazione Trouser, parallelo 10 / * N/mm ISO 6383-1
Resistenza alla lacerazione Trouser, perpend. 10 / * N/mm ISO 6383-1
WVTR, 23°C/85%r.h. 6 / * g/(m²*d) ISO 15106-1/-2
Permeabilità all' Ossigeno, 23°C/0%r.h. 4 / * cm³/(m²*d*bar) ISO 15105-1/-2
Permeabilità all' Ossigeno, 23°C/85%r.h. 4 / * cm³/(m²*d*bar) ISO 15105-1/-2
Permeabilità al CO2, 23°C/0%r.h. 15 / * cm³/(m²*d*bar) ISO 15105-1/-2
Permeabilità al CO2, 23°C/85%r.h. 15 / * cm³/(m²*d*bar) ISO 15105-1/-2
Caratteristiche
Processabilità e Forma di Forni
Estrusione Film, Altre Estrusioni, Rivestimento, Soffiaggio
Forma fisica disponibile
Granuli, Colore naturale
Caratteristiche speciali
Trasparente
Caratteristiche
Proprietà di barriera
Certifications
Contatto con gli alimenti, Approvato per l'utilizzo per contatto con alimenti secondo la FDA 21 CFR
Applicazioni
Medicale, Imballaggio
Disponibilità geografica
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.