Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultradur® B 4300 G2 - PBT-GF10 - BASF

Material Data Center offers the following functions for Ultradur® B 4300 G2:
unit conversion, PDF datasheet print, comparison with other plastics, application examples, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Ultradur datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informations produit
Injection molding grade with 10 % glass fibers for technical parts,rigid, tough and dimensionally stable, e.g. switches, connectors and small automotive parts.
The products can also be offered as BMBcert™ and/or Ccycled™. Due to the Massbalance approach the product properties do not change

Abbreviated designation according to ISO 1043: PBT-GF10
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Indice de fluidité à chaud en volume, MVR 16 cm³/10min ISO 1133
Température 250 °C -
Charge 2.16 kg -
Retrait au moulage, parallèle 1.2 % ISO 294-4, 2577
Retrait au moulage, perpendiculaire 1.4 % ISO 294-4, 2577
ASTM Data
Retrait au moulage , parallèle 0.008 mm/mm ASTM D 955
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 4400 MPa ISO 527
Contrainte à la rupture 80 MPa ISO 527
Déformation à la rupture 4.5 % ISO 527
Résistance au choc Charpy, +23°C 37 kJ/m² ISO 179/1eU
Résistance au choc Charpy, -30°C 38 kJ/m² ISO 179/1eU
Résistance au choc Charpy (entaillé), +23°C 3.5 kJ/m² ISO 179/1eA
ASTM Data
Module en traction 4482 MPa ASTM D 638
Résistance de traction à la rupture 90.3 MPa ASTM D 638
Allongement à la rupture 3.5 % ASTM D 638
Module de flexion 3930 MPa ASTM D 790
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fusion, 10°C/min 223 °C ISO 11357-1/-3
Température de fléchissement s/chrg, 1.80 MPa 165 °C ISO 75-1/-2
Température de fléchissement s/chrg, 0.45 MPa 210 °C ISO 75-1/-2
Coeffic. de dilatation therm. linéique, parallèle 60 E-6/K ISO 11359-1/-2
Coeffic. de dilatation therm. linéique, perpend. 125 E-6/K ISO 11359-1/-2
Inflammabilité ep. nom. 1.5 mm HB class IEC 60695-11-10
Epaisseur de l'éprouvette 1.5 mm -
Yellow Card disponible oui - -
Inflammabilité pr. épaisseur h HB class IEC 60695-11-10
Epaisseur de l'éprouvette 0.8 mm -
Yellow Card disponible oui - -
Aptitude à l'allumage 19.5 % ISO 4589-1/-2
ASTM Data
DTUL à 66 psi 220 °C ASTM D 648
DTUL à 264 psi 200 °C ASTM D 648
Température de fusion 223 °C ASTM D 3418
Propriétés électriquesValeurUnitéNorme du test
ISO Data
Permittivité relative, 100Hz 3.6 - IEC 62631-2-1
Permittivité relative, 1MHz 3.6 - IEC 62631-2-1
Facteur de pertes, 100Hz 12 E-4 IEC 62631-2-1
Facteur de pertes, 1MHz 150 E-4 IEC 62631-2-1
Résistivité transversale >1E13 Ohm*m IEC 62631-3-1
Résistivité superficielle 1E13 Ohm IEC 62631-3-2
Rigidité diélectrique 37 kV/mm IEC 60243-1
Indice de résistance au cheminement 300 - IEC 60112
Propriétés diversesValeurUnitéNorme du test
Absorption d'eau 0.4 % Sim. to ISO 62
Absorption d'humidité 0.2 % Sim. to ISO 62
Masse volumique 1370 kg/m³ ISO 1183
Densité 1370 kg/m³ ASTM D 792
Propriétés spécifiques à la matièreValeurUnitéNorme du test
ISO Data
Indice de viscosité 115 cm³/g ISO 307, 1157, 1628
Fonctions
Viscosité / Vitesse de cisaillement , Ultradur® B 4300 G2, PBT-GF10, BASF
Contrainte de cisaillement / Vit. de cisaillement , Ultradur® B 4300 G2, PBT-GF10, BASF
Contrainte / Déformation , Ultradur® B 4300 G2, PBT-GF10, BASF
Module sécant / Déformation , Ultradur® B 4300 G2, PBT-GF10, BASF
Contrainte / Déformation (isochrone) 23°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Module de fluage / Temps 23°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Courbe de fluage 23°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Contrainte / Déformation (isochrone) 40°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Module de fluage / Temps 40°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Courbe de fluage 40°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Contrainte / Déformation (isochrone) 90°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Module de fluage / Temps 90°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Courbe de fluage 90°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Contrainte / Déformation (isochrone) 120°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Module de fluage / Temps 120°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Courbe de fluage 120°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Contrainte / Déformation (isochrone) 160°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Module de fluage / Temps 160°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Courbe de fluage 160°C, Ultradur® B 4300 G2, PBT-GF10, BASF
Volume spécifique (pvT) , Ultradur® B 4300 G2, PBT-GF10, BASF
Module de traction / Température , Ultradur® B 4300 G2, PBT-GF10, BASF
Caractéristiques
Transformation
Moulage par injection
Conditionnement
Granulés, Couleurs naturelles
Additifs
Lubrifiant
Propriétés spéciales
Stabilisé à la lumière, Stabilisé aux intempéries, Stabilisé à la chaleur
Disponibilité régionale
Autres informations
Moulages par injection
PREPROCESSING
Pre/Post-processing, max. allowed water content: .04 %
Pre/Post-processing, Pre-drying, Temperature: 80 - 120 °C
Pre/Post-processing, Pre-drying, Time: 4 h

PROCESSING
injection molding, Melt temperature, range: 250 - 275 °C
injection molding, Melt temperature, recommended: 260 °C
injection molding, Mold temperature, range: 60 - 100 °C
injection molding, Mold temperature, recommended: 80 °C
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.