Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of NORYL™ Resin GFN30F - Asia - (PPE+PS)-GF30 - Saudi Basic Industries Corporation (SABIC)

Material Data Center offers the following functions for NORYL™ Resin GFN30F - Asia:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Noryl datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informations produit
NORYL™ GFN30F resin is a 30% glass reinforced blend of polyphenylene ether (PPE) + high impact polystyrene (HIPS). This injection moldable grade exhibits very low moisture absorption, high strength, hydrolytic stability, Low warpage, low specific gravity, and dimensional stability. NORYL GFN30F carries a UL746C outdoor suitability rating of F2 along with FDA food contact compliance and NSF 61 listings in several colors. The properties of this material makes it an excellent candidate for water management applications such as water filter and meter components, pump housings / impellers, shower + faucet, and valves.*See NORYL GFN30 resin for NON FDA / NSF version.

UL Yellow Card Link E45587-237022
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Indice de fluidité à chaud en volume, MVR 2 cm³/10min ISO 1133
Température 280 °C -
Charge 5 kg -
ASTM Data
Indice de fluidité, MFI 3.2 g/10min ASTM D 1238
Température 280 °C -
Charge 5 kg -
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 8200 MPa ISO 527
Contrainte à la rupture 110 MPa ISO 527
Déformation à la rupture 2.5 % ISO 527
Module de flexion 6800 MPa ISO 178
Résistance au choc Charpy (entaillé), +23°C 8 kJ/m² ISO 179/1eA
Izod impact strength, +23°C, 4mm 30 kJ/m² ISO 180/1U
Résistance au choc Izod (entaillé), +23°C, 4mm 11 kJ/m² ISO 180/1A
Résistance au choc Izod (entaillé), -30°C, 4mm 10 kJ/m² ISO 180/1A
ASTM Data
Module en traction 8600 MPa ASTM D 638
Résistance de traction à la rupture 130 MPa ASTM D 638
Allongement à la rupture 3 % ASTM D 638
Module de flexion 7200 MPa ASTM D 790
Izod choc avec entaille, 1/8 in 100 J/m ASTM D 256
Izod choc avec entaille, bas température 120 J/m ASTM D 256
Température -30 °C -
Résistance au choc Izod, 1/8 in 590 J/m ASTM D 256
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fléchissement s/chrg, 1.80 MPa 139 °C ISO 75-1/-2
Température de ramolliss. Vicat, B 147 °C ISO 306
Température de ramolliss. Vicat, 120°C/h 50N 149 °C ISO 306
Inflammabilité ep. nom. 1.5 mm HB class IEC 60695-11-10
Epaisseur de l'éprouvette 1.5 mm -
ASTM Data
DTUL à 66 psi 147 °C ASTM D 648
DTUL à 264 psi 139 °C ASTM D 648
Vicat température 147 °C ASTM D 1525
Propriétés diversesValeurUnitéNorme du test
Absorption d'eau 0.1 % Sim. to ISO 62
Absorption d'humidité 0.04 % Sim. to ISO 62
Densité 1310 kg/m³ ASTM D 792
Recommandations pour la transformation Moulage par injectionValeurUnitéNorme du test
Pré-séchage - température 110 - 120 °C -
Pré-séchage - temps 3 - 4 h -
L'humidité de traitement ≤0.02 % -
Température de la matière fondue 300 - 325 °C -
Température du moule 80 - 110 °C -
Zone 1 265 - 315 °C -
Zone 2 275 - 320 °C -
Zone 3 290 - 325 °C -
Vitesse de rotation de vis 20 - 100 rpm -
Contre-pression 0.3 - 0.7 MPa -
Caractéristiques
Transformation
Moulage par injection
Résistance Chimique
Stabilité hydrolytique
Certifications
Contact alimentaire, FDA 21 CFR approbation
Disponibilité régionale
Asia Pacific
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.