Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Makrolon® FR6005 HF - PC - Covestro Deutschland AG

Material Data Center offers the following functions for Makrolon® FR6005 HF:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Makrolon datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Indice de fluidité à chaud en volume, MVR 16 cm³/10min ISO 1133
Température 300 °C -
Charge 1.2 kg -
Retrait au moulage, parallèle 0.7 % ISO 294-4, 2577
Retrait au moulage, perpendiculaire 0.7 % ISO 294-4, 2577
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 2310 MPa ISO 527
Contrainte d'écoulement 60 MPa ISO 527
Déformation au seuil d'écoulement 5.7 % ISO 527
Déformation nominale à la rupture >50 % ISO 527
Contrainte à la rupture 55 MPa ISO 527
Déformation à la rupture 100 % ISO 527
Module de flexion, 23°C 2320 MPa ISO 178
Résistance à la flexion 92 MPa ISO 178
Résistance au choc Charpy (entaillé), +23°C 56 kJ/m² ISO 179/1eA
Type de défaillance P - -
Résistance au choc Charpy (entaillé), -30°C 18 kJ/m² ISO 179/1eA
Type de défaillance C - -
Résistance au choc Izod avec entaille, +23°C 56[1] kJ/m² ISO 180/1A
Résistance au choc Izod avec entaille 16[1] kJ/m² ISO 180/1A
Température -30 °C -
Perforation - force maximum, +23°C 5000 N ISO 6603-2
Perforation - Energie, +23°C 51 J ISO 6603-2
1: 3 mm
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fléchissement s/chrg, 1.80 MPa 118 °C ISO 75-1/-2
Température de fléchissement s/chrg, 0.45 MPa 133 °C ISO 75-1/-2
Température de ramolliss. Vicat, B 138 °C ISO 306
Coeffic. de dilatation therm. linéique, parallèle 61 E-6/K ISO 11359-1/-2
Coeffic. de dilatation therm. linéique, perpend. 66 E-6/K ISO 11359-1/-2
Inflammabilité ep. nom. 1.5 mm V-0 class IEC 60695-11-10
Epaisseur de l'éprouvette 1.5 mm -
Inflammabilité pr. épaisseur h V-0 class IEC 60695-11-10
Epaisseur de l'éprouvette 3.0 mm -
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (1) 1.5 mm -
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (2) 3 mm -
Glow Wire Ignition Temperature (GWIT) 850 °C IEC 60695-2-13
GWIT - thickness tested (1) 1.5 mm -
Glow Wire Ignition Temperature (GWIT) 900 °C IEC 60695-2-13
GWIT - thickness tested (2) 3 mm -
Propriétés diversesValeurUnitéNorme du test
Masse volumique 1200 kg/m³ ISO 1183
Préparation et conditionnement des éprouvettesValeurUnitéNorme du test
ISO Data
Injection, température de la matière fondue 300 °C ISO 294
Injection, température du moule 80 °C ISO 294
injection, vitesse d'injection 200 mm/s ISO 294
Recommandations pour la transformation Moulage par injectionValeurUnitéNorme du test
Pré-séchage - température 120 °C -
Pré-séchage - temps 2 - 3 h -
L'humidité de traitement ≤0.02 % -
Température de la matière fondue 280 - 320 °C -
Température du moule 80 - 120 °C -
Zone 1 250 - 260 °C -
Zone 2 270 - 280 °C -
Zone 3 280 - 290 °C -
Température de la buse 290 - 300 °C -
Contre-pression 5 - 15 MPa -
Caractéristiques
Transformation
Moulage par injection
Additifs
Agent de démoulage
Propriétés spéciales
Ignifugé, Modifié choc
Applications
Électrotechnique et électrique
Disponibilité régionale
Amérique du nord, Europe, Asia Pacific, South and Central America, Proche-Orient/Afrique
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.