Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of EMERGE™ PC/ABS 7700 EU - (PC+ABS) - Trinseo

Material Data Center offers the following functions for EMERGE™ PC/ABS 7700 EU:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Emerge datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Indice de fluidité, MFI 12 g/10min ISO 1133
Température 260 °C -
Charge 2.16 kg -
Retrait au moulage, parallèle 0.5 % ISO 294-4, 2577
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 2500 MPa ISO 527
Contrainte d'écoulement 56 MPa ISO 527
Déformation au seuil d'écoulement 3.8 % ISO 527
Contrainte à la rupture 45 MPa ISO 527
Déformation à la rupture 52 % ISO 527
Résistance au choc Charpy (entaillé), +23°C 50 kJ/m² ISO 179/1eA
Résistance au choc Charpy (entaillé), -30°C 16 kJ/m² ISO 179/1eA
Résistance au choc Izod avec entaille, +23°C 50 kJ/m² ISO 180/1A
Résistance au choc Izod avec entaille 17 kJ/m² ISO 180/1A
Température -30 °C -
ASTM Data
Module en traction 2550 MPa ASTM D 638
Module de traction d’élasticité 57 MPa ASTM D 638
Résistance de traction à la rupture 48 MPa ASTM D 638
Allongement d’élasticité 3.8 % ASTM D 638
Allongement à la rupture 100 % ASTM D 638
Module de flexion 2450 MPa ASTM D 790
Résistance à la flexion 86 MPa ASTM D 790
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fléchissement s/chrg, 1.80 MPa 78 °C ISO 75-1/-2
Température de fléchissement s/chrg, 0.45 MPa 89 °C ISO 75-1/-2
Température de ramolliss. Vicat, A 104 °C ISO 306
Température de ramolliss. Vicat, B 94 °C ISO 306
Inflammabilité ep. nom. 1.5 mm V-0 class IEC 60695-11-10
Epaisseur de l'éprouvette 1.5 mm -
Inflammabilité 5V pr. épaisseur h 5VA class IEC 60695-11-20
Epaisseur de l'éprouvette 2.5 mm -
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (1) 2 mm -
ASTM Data
coefficient de dilatation thermique, long. 68 E-6/K ASTM D 696
Coefficient de dilatation thermique, trav. 68 E-6/K ASTM D 696
Propriétés électriquesValeurUnitéNorme du test
ISO Data
Permittivité relative, 100Hz 2.86 - IEC 62631-2-1
Permittivité relative, 1MHz 2.8 - IEC 62631-2-1
Facteur de pertes, 100Hz 40 E-4 IEC 62631-2-1
Facteur de pertes, 1MHz 70 E-4 IEC 62631-2-1
Résistivité transversale 1E16 Ohm*m IEC 62631-3-1
Résistivité superficielle 5.2E15 Ohm IEC 62631-3-2
Rigidité diélectrique 26 kV/mm IEC 60243-1
Propriétés diversesValeurUnitéNorme du test
Masse volumique 1180 kg/m³ ISO 1183
Recommandations pour la transformation Moulage par injectionValeurUnitéNorme du test
Pré-séchage - température 80 - 90 °C -
Pré-séchage - temps 3 - 4 h -
Température de la matière fondue 240 - 275 °C -
Température du moule 60 - 90 °C -
Caractéristiques
Transformation
Moulage par injection
Propriétés spéciales
Ignifugé, Stabilisé aux intempéries
Certifications
Grade médical, Biocompatibility ISO 10993
Applications
Médical
Disponibilité régionale
Europe, Proche-Orient/Afrique
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.