Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Topester™ 428RM - TPC - Top Polymer Enterprise

Material Data Center offers the following functions for Topester™ 428RM:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other Topester datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
Topester™ 428RM  is completely recyclable.
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt flow index, MFI 16 g/10min ISO 1133
Temperature 230 °C -
Load 2.16 kg -
Molding shrinkage, parallel 1.1 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
ISO Data
Stress at break 18 MPa ISO 527
Strain at break 940 % ISO 527
Flexural modulus 30 MPa ISO 178
Charpy notched impact strength, +23°C N kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C N kJ/m² ISO 179/1eA
Shore D hardness 28 - ISO 7619-1
Thermal propertiesValueUnitTest Standard
ISO Data
Melting temperature, 10°C/min 170 °C ISO 11357-1/-3
Vicat softening temperature, A 80 °C ISO 306
Electrical propertiesValueUnitTest Standard
ISO Data
Volume resistivity 1E10 Ohm*m IEC 62631-3-1
Other propertiesValueUnitTest Standard
Density 1070 kg/m³ ISO 1183
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 110 °C -
Pre-drying - Time 3 - 5 h -
Mold temperature 20 - 60 °C -
Zone 1 180 - 200 °C -
Zone 2 180 - 200 °C -
Zone 3 200 - 220 °C -
Nozzle temperature 200 - 230 °C -
Processing Recommendation ExtrusionValueUnitTest Standard
Type of extrusion wire/cable - -
Pre-drying - Temperature 110 °C -
Pre-drying - Time 3 - 5 h -
Zone 1 180 - 200 °C -
Zone 2 180 - 210 °C -
Zone 3 180 - 210 °C -
Characteristics
Processing
Injection Molding, Other Extrusion
Delivery form
Pellets, Natural Color
Special Characteristics
Heat stabilized or stable to heat
Applications
Automotive
Regional Availability
Asia Pacific
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.