Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of CELEX™ 5200HF.K - (PC+ABS) - Trinseo

Material Data Center offers the following functions for CELEX™ 5200HF.K:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other Celex datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical CharacteristicsValueUnitTest Standard
ASTM Data
Melt Flow Index, MFI 18 g/10min ASTM D 1238
Temperature 230 °C -
Load 3.8 kg -
Mold Shrinkage, MD 0.006 mm/mm ASTM D 955
Mechanical propertiesValueUnitTest Standard
ASTM Data
Tensile Modulus 2448 MPa ASTM D 638
Tensile Strength 55 MPa ASTM D 638
Elongation at Break 100 % ASTM D 638
Flexural Modulus 2599 MPa ASTM D 790
Flexural Strength 88.3 MPa ASTM D 790
Izod Impact notched, 1/8 in 747 J/m ASTM D 256
Izod Impact notched, Low-Temperature 219 J/m ASTM D 256
Temperature -20 °C -
Thermal propertiesValueUnitTest Standard
ASTM Data
UL 94 Flame rating V-0 - UL 94
Thickness tested 1.4 mm -
DTUL @ 264 psi 76.1 °C ASTM D 648
Vicat Temperature 100 °C ASTM D 1525
Electrical propertiesValueUnitTest Standard
ISO Data
Comparative tracking index 600 - IEC 60112
ASTM Data
Dielectric Strength, Short Time 26 kV/mm ASTM D 149
Volume Resistivity 1E11 Ohm*cm ASTM D 257
Other propertiesValueUnitTest Standard
Density 1180 kg/m³ ASTM D 792
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 80 °C -
Pre-drying - Time 3 - 4 h -
Mold temperature 40 - 60 °C -
Zone 1 190 - 220 °C -
Zone 2 200 - 225 °C -
Zone 3 205 - 235 °C -
Nozzle temperature 210 - 235 °C -
Characteristics
Processing
Injection Molding
Features
Copolymer
Applications
IT / Business Machine, Encapsulation
Regional Availability
Asia Pacific
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.