Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAKEEP® i4 G - PEEK - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAKEEP® i4 G:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vestakeep datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
商品の説明文
Implantable grade polyether ether ketone resin for permanent implants

VESTAKEEP® i4 G is a natural colored, high viscosity polyether ether ketone (PEEK) that is especially designed for long term implantable medical devices. This grade is often used for extrusion processing technologies.

Proven Biocompatibility of VESTAKEEP® i-Grades
The extra high purity and extended quality measures make VESTAKEEP® i-Grade materials an excellent choice for permanent implants.

For VESTAKEEP® i4 G, biocompatibility has been tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI.

VESTAKEEP® i4 G complies ASTM F2026 “Standard Specification for Polyetheretherketone (PEEK) Polymers for Surgical Implant Applications”.

A summary of biocompatibility test results is available upon request.

Biocompatibility tests available for i4 G


Processing of VESTAKEEP® i-Grades
VESTAKEEP® i4 G can be processed by common melt processing techniques like injection molding and extrusion.

We recommend a melt temperature between 370°C and 380°C during the injection molding process. The mold temperature should be within a range of 160°C to 200°C, preferably 180°C.

Our technical experts would appreciate to give you support regarding the special requirements for the processing of VESTAKEEP® i4 G.

Delivery of VESTAKEEP® i-Grades
VESTAKEEP® i4 G is supplied as cylindrical pellets in 10 kg boxes with moisture-proof polyethylene liners.


FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.EVONIK.COM/MEDICAL-TECHNOLOGY
Processing/Physical Characteristics単位テスト基準
ISO データ
メルトボリュームレイト, MVR 12 cm³/10min ISO 1133
温度 380 °C -
荷重 5 kg -
機械的特性単位テスト基準
ISO データ
引張弾性率 3500 MPa ISO 527
降伏応力 94 MPa ISO 527
降伏ひずみ 5 % ISO 527
破壊呼びひずみ >50 % ISO 527
シャルピー衝撃強さ, +23°C N kJ/m² ISO 179/1eU
シャルピー衝撃強さ, -30°C N kJ/m² ISO 179/1eU
ノッチ付きシャルピー衝撃強さ, +23°C 9.1 kJ/m² ISO 179/1eA
Type of failure C - -
ノッチ付きシャルピー衝撃強さ, -30°C 6 kJ/m² ISO 179/1eA
Type of failure C - -
熱的特性単位テスト基準
ISO データ
溶融温度, 10°C/min 338 °C ISO 11357-1/-3
ガラス転移点, 10°C/min 152 °C ISO 11357-1/-2
荷重たわみ温度, 1.80 MPa 150 °C ISO 75-1/-2
荷重たわみ温度, 0.45 MPa 205 °C ISO 75-1/-2
ビカット軟化温度, B 305 °C ISO 306
その他の特性.単位テスト基準
吸水率 0.4 % Sim. to ISO 62
吸湿率 0.12 % Sim. to ISO 62
密度 1300 kg/m³ ISO 1183
特殊な特性
成形加工法.
射出成形., その他の押出成形.
納入形状.
ペレット., ナチュラルカラー
Certifications
Medical Grade, Biocompatibility ISO 10993, US Pharmacopeia Class VI Approved
アプリケーション
医療の
領域別の利用可能性
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.