Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of XANTAR™ G4F 22 UR - PC-GF20 FR - Mitsubishi Engineering-Plastics Corporation

Material Data Center offers the following functions for XANTAR™ G4F 22 UR:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, cooling time calculation, CAE Interfaces

Check here, which other Xantar datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
20% Glass Reinforced, Flame Retardant, UV Stabilized

ISO 1043 PC-GF20 FR

XANTAR Polycarbonate & Blends, your global partner for innovative added value
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 8 cm³/10min ISO 1133
Temperature 300 °C -
Load 1.2 kg -
Molding shrinkage, parallel 0.2 % ISO 294-4, 2577
Molding shrinkage, normal 0.5 % ISO 294-4, 2577
Density of melt 1170 kg/m³ -
Thermal conductivity of melt 0.29 W/(m K) -
Spec. heat capacity of melt 1530 J/(kg K) -
Eff. thermal diffusivity 1.62E-7 m²/s -
Ejection temperature 134 °C -
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 6000 MPa ISO 527
Stress at break 90 MPa ISO 527
Strain at break 4 % ISO 527
Thermal propertiesValueUnitTest Standard
ISO Data
Temp. of deflection under load, 1.80 MPa 145 °C ISO 75-1/-2
Vicat softening temperature, B 150 °C ISO 306
Coeff. of linear therm. expansion, parallel 25 E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. V-0 class IEC 60695-11-10
Thickness tested 1.5 mm -
Yellow Card available yes - -
Burning Behav. at thickness h V-0 class IEC 60695-11-10
Thickness tested 1.2 mm -
Yellow Card available yes - -
Oxygen index 35 % ISO 4589-1/-2
Electrical propertiesValueUnitTest Standard
ISO Data
Relative permittivity, 100Hz 3.25 - IEC 62631-2-1
Relative permittivity, 1MHz 3.2 - IEC 62631-2-1
Dissipation factor, 100Hz 9 E-4 IEC 62631-2-1
Dissipation factor, 1MHz 90 E-4 IEC 62631-2-1
Volume resistivity >1E13 Ohm*m IEC 62631-3-1
Surface resistivity >1E15 Ohm IEC 62631-3-2
Electric strength 29 kV/mm IEC 60243-1
Comparative tracking index 200 - IEC 60112
Other propertiesValueUnitTest Standard
Water absorption 0.29 % Sim. to ISO 62
Density 1350 kg/m³ ISO 1183
Test specimen productionValueUnitTest Standard
ISO Data
Injection Molding, melt temperature 300 °C ISO 294
Injection Molding, mold temperature 100 °C ISO 294
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 120 °C -
Pre-drying - Time 4 h -
Processing humidity ≤0.03 % -
Melt temperature 290 - 320 °C -
Mold temperature 80 - 120 °C -
Zone 1 260 - 280 °C -
Zone 2 270 - 290 °C -
Zone 3 280 - 300 °C -
Nozzle temperature 270 - 290 °C -
Diagrams
Stress-strain , XANTAR™ G4F 22 UR, PC-GF20 FR, Mitsubishi EP
Secant modulus-strain , XANTAR™ G4F 22 UR, PC-GF20 FR, Mitsubishi EP
Specific volume-temperature (pvT) , XANTAR™ G4F 22 UR, PC-GF20 FR, Mitsubishi EP
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Release agent
Special Characteristics
Flame retardant, Light stabilized or stable to light, U.V. stabilized or stable to weather, Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.