Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VALOX™ FR Resin ENH8560 - Europe - (PBT+PET)-GF30 - Saudi Basic Industries Corporation (SABIC)

Material Data Center offers the following functions for VALOX™ FR Resin ENH8560 - Europe:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Valox datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
VALOX ENH8560 is a 30% glass reinforced, non-chlorinated/brominated flame retardant Polybutylene Terephthalate/Polyethylene Terephthalate (PBT/PET) injection moldable grade with excellent chemical resistance. It has a UL94V0@1.5mm and 5VA@2.0mm flame rating. This is a good candidate for a variety of applications needing a sustainable FR PBT/PET solution.

UL Yellow Card Link E45329-100705592
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 25 cm³/10min ISO 1133
Temperature 265 °C -
Load 5 kg -
Melt flow index, MFI 11 g/10min ISO 1133
Temperature 250 °C -
Load 5 kg -
ASTM Data
Melt Flow Index, MFI 5 g/10min ASTM D 1238
Temperature 265 °C -
Load 2.16 kg -
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 12000 MPa ISO 527
Yield stress 105 MPa ISO 527
Yield strain 1 % ISO 527
Stress at break 105 MPa ISO 527
Strain at break 2 % ISO 527
Flexural modulus 10000 MPa ISO 178
Charpy notched impact strength, +23°C 5 kJ/m² ISO 179/1eA
Izod impact strength, +23°C, 4mm 30 kJ/m² ISO 180/1U
Izod impact strength, -30°C, 4mm 27 kJ/m² ISO 180/1U
Izod notched impact strength, +23°C, 4mm 7 kJ/m² ISO 180/1A
Izod notched impact strength, -30°C, 4mm 7 kJ/m² ISO 180/1A
Rockwell hardness R 118 - ISO 2039-2
Ball indentation hardness 166 MPa ISO 2039-1
ASTM Data
Tensile Modulus 12000 MPa ASTM D 638
Tensile Strength at Yield 103 MPa ASTM D 638
Tensile Strength at Break 103 MPa ASTM D 638
Elongation at Yield 1 % ASTM D 638
Elongation at Break 2 % ASTM D 638
Flexural Modulus 10000 MPa ASTM D 790
Izod Impact notched, 1/8 in 60 J/m ASTM D 256
Izod Impact notched, Low-Temperature 60 J/m ASTM D 256
Temperature -30 °C -
Izod Impact unnotched, 1/8 in 450 J/m ASTM D 256
Thermal propertiesValueUnitTest Standard
ISO Data
Temp. of deflection under load, 1.80 MPa 180 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 215 °C ISO 75-1/-2
Vicat softening temperature, A 215 °C ISO 306
Vicat softening temperature, B 203 °C ISO 306
Vicat softening temperature, 120°C/h 50N 201 °C ISO 306
Burning behav. at 1.5 mm nom. thickn. V-0 class IEC 60695-11-10
Thickness tested 1.5 mm -
Burning behav. 5V at thickness h 5VA class IEC 60695-11-20
Thickness tested 2.0 mm -
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
Glow Wire Ignition Temperature (GWIT) 750 °C IEC 60695-2-13
GWIT - thickness tested (1) 1 mm -
Glow Wire Ignition Temperature (GWIT) 775 °C IEC 60695-2-13
GWIT - thickness tested (2) 2 mm -
Glow Wire Ignition Temperature (GWIT) 825 °C IEC 60695-2-13
GWIT - thickness tested (3) 3 mm -
ASTM Data
DTUL @ 66 psi 210 °C ASTM D 648
DTUL @ 264 psi 196 °C ASTM D 648
Vicat Temperature 196 °C ASTM D 1525
Electrical propertiesValueUnitTest Standard
ISO Data
Relative permittivity, 1MHz 3.6 - IEC 62631-2-1
Dissipation factor, 1MHz 120 E-4 IEC 62631-2-1
Volume resistivity 1E13 Ohm*m IEC 62631-3-1
Surface resistivity >1E15 Ohm IEC 62631-3-2
Electric strength 35 kV/mm IEC 60243-1
Comparative tracking index 425 - IEC 60112
ASTM Data
Dielectric Strength, Short Time 8 kV/mm ASTM D 149
Dissipation Factor, 1 MHz 0.012 - ASTM D 150
Dielectric Constant, 1 MHz 3.6 - ASTM D 150
Volume Resistivity 1E15 Ohm*cm ASTM D 257
Other propertiesValueUnitTest Standard
Water absorption 0.3 % Sim. to ISO 62
Humidity absorption 0.05 % Sim. to ISO 62
Density 1580 kg/m³ ISO 1183
Water Absorption, 24hr 0.07 % ASTM D 570
Density 1580 kg/m³ ASTM D 792
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 110 - 120 °C -
Pre-drying - Time 4 - 6 h -
Processing humidity ≤0.02 % -
Melt temperature 260 - 285 °C -
Mold temperature 60 - 110 °C -
Feed temperature 40 - 60 °C -
Zone 1 240 - 260 °C -
Zone 2 255 - 280 °C -
Zone 3 260 - 280 °C -
Characteristics
Processing
Injection Molding
Additives
Flame retarding agent
Special Characteristics
Flame retardant
Chemical Resistance
General Chemical Resistance
Regional Availability
Europe
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.