Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Novodur® Ultra 4105 - (ABS+PC) - INEOS Styrolution

Material Data Center offers the following functions for Novodur® Ultra 4105:
unit conversion, PDF datasheet print, comparison with other plastics, flow length calculation, snap fit calculation, beam deflection calculation, cooling time calculation, parameters for material models, CAE Interfaces

Check here, which other Novodur datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
Medium high heat grade with superior impact resistance, PC-modified, low emission

ISO Shortname: ISO 2580-1 -ABS 2-X, MG, 105-04-35-20
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 14 cm³/10min ISO 1133
Temperature 260 °C -
Load 5 kg -
Density of melt 910 kg/m³ -
Thermal conductivity of melt 0.131 W/(m K) -
Spec. heat capacity of melt 1800 J/(kg K) -
Ejection temperature 85 °C -
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 2000 MPa ISO 527
Yield stress 45 MPa ISO 527
Yield strain 3.7 % ISO 527
Nominal strain at break 15 % ISO 527
Charpy notched impact strength, +23°C 40 kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C 30 kJ/m² ISO 179/1eA
Thermal propertiesValueUnitTest Standard
ISO Data
Temp. of deflection under load, 1.80 MPa 99 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 108 °C ISO 75-1/-2
Vicat softening temperature, B 106 °C ISO 306
Coeff. of linear therm. expansion, parallel 90 E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 90 E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. HB class IEC 60695-11-10
Thickness tested 1.6 mm -
Electrical propertiesValueUnitTest Standard
ISO Data
Relative permittivity, 100Hz 3 - IEC 62631-2-1
Relative permittivity, 1MHz 3 - IEC 62631-2-1
Dissipation factor, 100Hz 38 E-4 IEC 62631-2-1
Dissipation factor, 1MHz 86 E-4 IEC 62631-2-1
Volume resistivity >1E13 Ohm*m IEC 62631-3-1
Surface resistivity >1E15 Ohm IEC 62631-3-2
Other propertiesValueUnitTest Standard
Density 1070 kg/m³ ISO 1183
Test specimen productionValueUnitTest Standard
ISO Data
Injection Molding, melt temperature 240 °C ISO 294
Injection Molding, mold temperature 70 °C ISO 294
Injection Molding, injection velocity 240 mm/s ISO 294
Diagrams
Viscosity-shear rate , Novodur® Ultra 4105, (ABS+PC), INEOS Styrolution
Shearstress-shear rate , Novodur® Ultra 4105, (ABS+PC), INEOS Styrolution
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Features
Low Emission
Regional Availability
Europe
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.